Beijer-electronics iX T15C EN Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Panneau de contrôle Beijer-electronics iX T15C EN. Beijer Electronics iX T15C EN User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
iXT15CInstallationGuide
1SafetyPrecautions
Both the installer and the owner and/or operator of the operator panel must read
and understand this installation manual.
1.1 General
Read the safety precautions carefully.
Check the delivery for transportation damage. If damage is found, notify the
supplier as soon as possible.
Do not use the operator panel in an environment with high explosive hazards.
The supplier is not responsible for modified, altered or reconstructed
equipment.
Use only parts and accessories manufactured according to specifications of
the supplier.
Read the installation and operating instructions carefully before installing,
using or repairing the operator panel.
Never allow fluids, metal filings or wiring debris to enter any openings in the
operator panel. This may cause fire or electrical shock.
Only qualified personnel may operate the operator panel.
Storingthe operatorpanel where the temperature is lower/higher than
recommended in this manual can cause the LCD display liquid to
congeal/become isotopic.
The LCD display liquid contains a powerful irritant. In case of skin contact,
wash immediately with plenty of water. In case of eye contact, hold the eye
open, flush with plenty of water and get medical attention.
Thefiguresinthismanualservesanillustrativepurpose. Becauseofthemany
variables associated with any particular installation, the supplier cannot
assume responsibility for actual use based on the figures.
The supplier neither guarantees that the operator panel is suitable for your
particular application, nor assumes responsibility for your product design,
installation or operation.
It is recommendedto turn on and shut down the operator panel at least once
before installing any components/cards or b efore connecting the operator
panel to external devices, like for example serial devices.
1.2 DuringInstallation
The operator panel is designed for stationary installation on a plane surface,
where the following conditions are fulfilled:
no high explosive risks
no strong magnetic fields
no direct sunlight
no large, sudden temperaturechanges
Install the product accordingto the accompanying installation instructions.
Ground the product according to the accompanying installation instructions.
Only qualified personnel may install the operator panel.
Separate the high voltage,signalandsupply cables.
Make sure that the voltage and polarity of the power source is correct before
connecting the product to the power outlet.
Peripheral equipment must be appropriate for the application and location.
1.3 DuringUse
Keep the operator panel clean.
Emergency stop and other safety functions may not be controlled from the
operator panel.
Do not use too much force or sharp objects when touching the keys ,
touchscreen etc.
1.4 ServiceandMaintenance
Only qualified personnel should carry out repairs.
The agreed warranty applies.
Before carrying out any cleaning or maintenance operations, disconnect the
equipment from the electrical supply.
Clean the display and surrounding f ront cover with a soft cloth and mild
detergent.
Replacing the battery incorrectly may result in explosion. Only use batteries
recommended by the supplier. During the warranty period, the battery needs
to be replaced by an authorized Beijer Electronics service center.
The unit can be reset by using the reset switch located behind the fan.
1.5 DismantlingandScrapping
The operator panel or parts thereof shall be recycled according to local
regulations.
The following components contain substances that might be hazardous
to health and the environment: lithium battery, electrolytic capacitor and
display.
1.6 AppearanceofAirinTouchScreen
The layer structure of the touch screencontainsairand in rare cases
appearance of bubbles can arise. This is purely cosmetic and does not affect
any functionality of the panel. The appearance can occur under cer tain
environmental conditions such as temperature, humidity, and atmospheric
pressure.
2Installation
2.1 SpaceRequirements
Maximum installation plate thickness: 8 mm
Space requirements in millimeters when installing the operator panel:
410 mm
286 mm
100 mm
50 mm
50 mm
100 mm
100 mm
Note:
Thedimensionsonthedrawingarenotproportional.
Caution:
Theopeningsontheenclosureare for airconvection. Donotcoverthese
openings.
2.2 InstallationProcess
The following is needed:
ATorxTX7screwdriver
1.
Unpack and check the delivery. If damage is found, notify the supplier.
Note:
Placetheoperatorpanelonastablesurfaceduring installation.
Droppingthepanelorlettingitfallmaycausedamage.
2.
Use the cut out dimensions that are included on the outline drawing, found
in section Operator Panel Drawings and in the Technical Data table, to cut a
correct opening in the cabinet. A separate cut out drawing is available for
download from the Beijer Electronics web site.
3.
Secure the operator panel in position by screwing the M4 Torx screw, allowing
the built-in bracket to tighten against the panel:
M4 x 20.7
0.4 Nm
4.
Connect the cables in the specified order, according to the drawing and steps
below.
Caution:
Ensurethattheoperatorpaneland thecontrollersystemhavethesame
electricalgrounding(referencevoltagelevel),otherwiseerrorsin
communicationmayoccur.
Theoperatorpanelmustbebroughttoambienttemperaturebeforeit
isstartedup. Ifcondensationforms,ensurethattheoperatorpanelis
drybeforeconnectingittothepoweroutlet.
Ensurethatthevoltageandp olarityofthepowersourceiscorrect.
Useonlyshieldedcommunicationcables.
Separatehighvoltagecablesfromsignaland supplycables.
24V DC
RS232/
RS422/
RS485
24V DC
A
D
Controller
Power
B
Ethernet
C
Connect cable A.
Connect cable B, using an M5 screw and a grounding conductor (as
short as possible) with a cross-section of minimu m 2.5 mm
2
.
Connect cable C.
Connect cable D. The recommended cross-section of the cable is
2.5 mm
2
.
5.
Carefully remove the laminated film over the operator panel display, to avoid
static electricity that could damage the panel.
2.2.1 ConnectionstotheController
For information about the cables to be used when connecting the operator panel to
the controller, please refer to the help file for the driver in question.
2.2.2 OtherConnectionsandPeripherals
Cables, p eripheral equipment and accessories must be suitable for the application
and its environment. For further details or recommendations, please refer to the
supplier.
3TechnicalData
Parameter iX T15C
Frontpanel,W×H×D
410×286×83mm
Cutoutdimensions,W×H
394×270mm
Mountingdepth 76mm(176mminclud ing clearance)
Standalonemounting
VESA100×100
Note: MaximumscrewlengthforVESA
mountingis5.5mm. Usageoflongers crews
mayleadtodamage.
Frontpanelseal
IP65
Rear panel seal
IP20
Touchscreenmaterial Polyesteronglass,resistive.
Overlay: AutotexF157orF207
(1)
.
Touchscreenoperations 1millionngertouchoperations
Reversesidematerial Powder-coated aluminum
Framematerial Powder-coated aluminum
Weight 5.4 kg
Serialportfor
COM1RS232 and
COM2RS422/RS485
9-pinD-subcontactwithRS232RTS/CTS,
chassis-mountedfemalewithstandard
lockingscrews4-40UNC
Note: RS422Interfaceisnotavailableyet.
Serialportfor
COM3RS232 and
COM4RS422/RS485
9-pinD-subcontactwithRS232RTS/CTS,
chassis-mountedfemalewithstandard
lockingscrews4-40UNC
Note: RS422Interfaceisnotavailableyet.
Ethernet 2×10/100/1000Base-T(shieldedRJ45)
USB 4×USBHost2.0,maxoutputcurrent500mA
Processor
Intel®Celero n® B810E(2×1.6GHz),
2MBL2Cache,Intel®QM67Chipset
Optional: Intel®Core™i32310E
(2×2.1GHz)(Hyperthreading),
3MBL2Cache,QM67Chipset
Optional: Intel®Core™i72715QE(4×2.1
GHz)(Turbo2.0,Hyperthreading),
6MBL2Cache,QM67Chipset
*forexactcongurationpleaseseepricelist
Externalstoragemedia
viaUSB
MemoryRAM 2GB*/4GB*DDR-3SO-DIMM1333MHz
*dependingonProcessorModule
LED
1×multi-color
Real time clock Y es (on chip)
Battery
LithiumbatterytypeBR2032(orCR2032),
exchangeable
Powerconsumptionat
ratedvoltage
114W
Fuse
10A
Power supply
DCinputrange: 18-32VDC(140W)ATX
standard
CE:Thepowersupplymustconformwiththe
requirementsaccordingtoIEC60950and
IEC61558-2-4.
ULandc UL: The power supplymustconform
withtherequirementsforclassIIpower
supplies.
Display TFT-LCD withLEDbacklight. 1280×800 pix-
els,16.7millioncolors
VGA
1×VGA:resolutionmax. 2048×1536@75Hz
DVI
1×DVI-DsingleLink: Resolutionmax.
1600×1200o r1920×1200(withreduced
blanking)
Activeareaof display,
W×H
331.2×207.0mm
Operatingtemperature 0°C+50°C
Storagetemperature -20°C+70°C
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Ethernet

iXT15CInstallationGuide1SafetyPrecautionsBoth the installer and the owner and/or operator of the operator panel must readand understand this installat

Page 2 - 5 OperatorPanelDrawings

ParameteriXT15CRelativehumidity 5- 8 5% non-condensedApprovalsandcertificationsInformationisavailableonthewebsitewww.beijerelectronics.com(1)Seesection

Commentaires sur ces manuels