EXTER™ K100Installation manualMAEN773D, 2008-05English

Page 2 - Foreword

Installation10 Beijer Electronics, MAEN773D3. Secure the operator panel in position, using all the fastening holes and the provided brackets and screw

Page 3 - Table of Contents

InstallationBeijer Electronics, MAEN773D 112.2.1 Mode SwitchesAll mode switches must be in OFF position during operator panel use.The mode switches sh

Page 4

Installation12 Beijer Electronics, MAEN773D

Page 5 - 1 Safety Precautions

Technical DataBeijer Electronics, MAEN773D 133Technical DataParameter EXTER K100Front panel, W x H x D 382 x 252 x 6 mm Mounting depth 58 mm (158 mm i

Page 6 - 1.3 During Installation

Technical Data14 Beijer Electronics, MAEN773D

Page 7 - 1.6 Dismantling and Scrapping

Chemical ResistanceBeijer Electronics, MAEN773D 154 Chemical Resistance4.1 Metal CasingThe frame and casing material is powder-coated aluminum. This p

Page 8 - Safety Precautions

Chemical Resistance16 Beijer Electronics, MAEN773DAutotex withstands DIN 42 115 Part 2 exposure of up to 1 hour duration to glacial acetic acid withou

Page 9 - 2 Installation

Operator Panel DrawingsBeijer Electronics, MAEN773D 175Operator Panel Drawings5.1 Communication PortsDrawing No. S-5005, Date 2004-10-27RS-232RS-422RS

Page 10 - 0.5 - 1.0 Nm

Operator Panel Drawings18 Beijer Electronics, MAEN773D5.2 EXTER K100 OutlineDrawing No. S-5083, Date 2004-10-14 (Revision date 2005-02-03)

Page 11 - 2.2.1 Mode Switches

Operator Panel DrawingsBeijer Electronics, MAEN773D 195.3 EXTER K100 Text StripDrawing No. S-5077, Date 2004-09-24

Page 12 - Installation

ForewordBeijer Electronics, MAEN773DInstallation manual for the EXTER series operator panelsForewordThe EXTER operator panel is developed to satisfy t

Page 13 - 3Technical Data

Operator Panel Drawings20 Beijer Electronics, MAEN773D

Page 14 - Technical Data

Additional Installation TipsBeijer Electronics, MAEN773D 216 Additional Installation TipsWhen experiencing communication problems in for example noisy

Page 15 - 4 Chemical Resistance

Additional Installation Tips22 Beijer Electronics, MAEN773D6.2 Ethernet Connection in the Panel1. In some industrial units for Ethernet, the RJ45 cont

Page 16 - 4.2.3 Autoflex EB

Additional Installation TipsBeijer Electronics, MAEN773D 236.3 To Achieve Better EMC Protection– Initially, use the original cabling from Beijer Elect

Page 17 - 5Operator Panel Drawings

Additional Installation Tips24 Beijer Electronics, MAEN773D6.4 Ambient TemperatureThe maximum ambient temperature for the operator panel is provided i

Page 18 - 5.2 EXTER K100 Outline

Additional Installation TipsBeijer Electronics, MAEN773D 256.5 SafetyMost of the operator panels are fed with 24 V DC.1. If you use a power supply tha

Page 19 - 5.3 EXTER K100 Text Strip

Additional Installation Tips26 Beijer Electronics, MAEN773D6.6 Galvanic IsolationThe operator panel has galvanic isolation against the 24 V DC feed bu

Page 20 - Operator Panel Drawings

Additional Installation TipsBeijer Electronics, MAEN773D 276.7 Cable and Bus Termination RS485– Use shielded and twisted pair cable. The pair capacita

Page 21 - Power supply

HEAD OFFICESWEDENBeijer Electronics Products ABBox 426SE-201 24 Malmö, SwedenTel: +46 40 35 86 00Fax: +46 40 93 23 [email protected]

Page 22

Table of ContentsBeijer Electronics, MAEN773DTable of Contents1 Safety Precautions...

Page 23 - Short distance

Table of ContentsBeijer Electronics, MAEN773D

Page 24 - 6.4 Ambient Temperature

Safety PrecautionsBeijer Electronics, MAEN773D 51 Safety PrecautionsBoth the installer and the owner and/or operator of the operator panel must read a

Page 25 - 6.5 Safety

Safety Precautions6 Beijer Electronics, MAEN773D1.2 General– Read the safety precautions carefully.– Check the delivery for transportation damage. If

Page 26 - 6.6 Galvanic Isolation

Safety PrecautionsBeijer Electronics, MAEN773D 71.4 During Use– Keep the operator panel clean.– Emergency stop and other safety functions may not be c

Page 27

Safety Precautions8 Beijer Electronics, MAEN773D

Page 28

InstallationBeijer Electronics, MAEN773D 92 Installation2.1 Space Requirements– Installation plate thickness: 1.5 - 9.0 mm (0.06 - 0.35 inch)– Space r