EXTER™ K20mInstallation manualMAEN852A, 2008-05English
Installation10 Beijer Electronics, MAEN852A3. Secure the operator panel in position, using all the fastening holes and the provided brackets and screw
InstallationBeijer Electronics, MAEN852A 112.2.1 Mode SwitchesAll mode switches must be in OFF position during operator panel use.The mode switches sh
Installation12 Beijer Electronics, MAEN852A
Technical DataBeijer Electronics, MAEN852A 133Technical DataParameter EXTER K20mFront panel, W x H x D 155 x 155 x 6 mmMounting depth 46.4 mmFront pa
Technical Data14 Beijer Electronics, MAEN852A
Chemical ResistanceBeijer Electronics, MAEN852A 154 Chemical Resistance4.1 Metal CasingThe frame and casing material is powder-coated aluminum. This p
Chemical Resistance16 Beijer Electronics, MAEN852AAutotex withstands DIN 42 115 Part 2 exposure of up to 1 hour duration to glacial acetic acid withou
Operator Panel DrawingsBeijer Electronics, MAEN852A 175Operator Panel Drawings5.1 Communication PortsDrawing No. S-05005RS-232RS-422RS-422/485RS-485
Operator Panel Drawings18 Beijer Electronics, MAEN852A5.2 EXTER K20m OutlineDrawing No. S-06840
Operator Panel DrawingsBeijer Electronics, MAEN852A 195.3 EXTER K20m Text StripDrawing No. S-068169.0(unit: mm)R1 (4x)Text max 15.5x7.5Text max 18.5x7
ForewordBeijer Electronics, MAEN852AInstallation manual for the EXTER series operator panelsForewordThe EXTER operator panel is developed to satisfy t
Operator Panel Drawings20 Beijer Electronics, MAEN852A
Additional Installation TipsBeijer Electronics, MAEN852A 216 Additional Installation TipsWhen experiencing communication problems in for example noisy
Additional Installation Tips22 Beijer Electronics, MAEN852A6.2 Ethernet Connection in the Panel1. In some industrial units for Ethernet, the RJ45 cont
Additional Installation TipsBeijer Electronics, MAEN852A 236.3 To Achieve Better EMC Protection– Initially, use the original cabling from Beijer Elect
Additional Installation Tips24 Beijer Electronics, MAEN852A6.4 Ambient TemperatureThe maximum ambient temperature for the operator panel is provided i
Additional Installation TipsBeijer Electronics, MAEN852A 256.5 SafetyMost of the operator panels are fed with 24 V DC.1. If you use a power supply tha
Additional Installation Tips26 Beijer Electronics, MAEN852A6.6 Galvanic IsolationThe operator panel has galvanic isolation against the 24 V DC feed bu
Additional Installation TipsBeijer Electronics, MAEN852A 276.7 Cable and Bus Termination RS485– Use shielded and twisted pair cable. The pair capacita
HEAD OFFICESWEDENBeijer Electronics Products ABBox 426SE-201 24 Malmö, SwedenTel: +46 40 35 86 00Fax: +46 40 93 23 [email protected]
Table of ContentsBeijer Electronics, MAEN852ATable of Contents1 Safety Precautions...
Table of ContentsBeijer Electronics, MAEN852A
Safety PrecautionsBeijer Electronics, MAEN852A 51 Safety PrecautionsBoth the installer and the owner and/or operator of the operator panel must read a
Safety Precautions6 Beijer Electronics, MAEN852A1.2 General– Read the safety precautions carefully.– Check the delivery for transportation damage. If
Safety PrecautionsBeijer Electronics, MAEN852A 71.4 During Use– Keep the operator panel clean.– Emergency stop and other safety functions may not be c
Safety Precautions8 Beijer Electronics, MAEN852A
InstallationBeijer Electronics, MAEN852A 92 Installation2.1 Space Requirements– Installation plate thickness: 1.5 - 7.5 mm (0.06 - 0.3 - inch)– Space