SCOM Protocol on RBCManualMAEN993, 2009-12English
Protocol Description and Timings10 Beijer Electronics, MAEN993Conditions for Response MessageThe conditions for a response message generated by the Be
Protocol Description and TimingsBeijer Electronics, MAEN993 11The Lr value depends on the command, for which the response message is generated. Detail
Protocol Description and Timings12 Beijer Electronics, MAEN993
Command ReferenceBeijer Electronics, MAEN993 135 Command ReferenceThe Lauer SCOM protocol exposes many commands for remote control of a Beijer Electro
Command Reference14 Beijer Electronics, MAEN9935.1 BRT Backlight BrightnessSets the backlight level to the given value. This command affects only the
Command ReferenceBeijer Electronics, MAEN993 15Example 1Set the backlight level of device at address 0.7 (group 0, address 7) to 130 (0x82):Device at
Command Reference16 Beijer Electronics, MAEN9935.2 MAN Manufacturer IDRequests the manufacturer ID from the device. The manufacturer ID is a short, ma
Command ReferenceBeijer Electronics, MAEN993 175.3 VER Unit ID and Model / Version NumberRequests the preassigned unit ID and model code, and the vers
Command Reference18 Beijer Electronics, MAEN9935.4 POT Local ControlEnables or disables the local backlight level control. If the local backlight cont
Command ReferenceBeijer Electronics, MAEN993 19Maximum Lr for this Command9Example 1Disable the local control of device at address 0.7 (group 0, addre
ForewordBeijer Electronics, MAEN993SCOM Protocol on RBCForewordThe Lauer SCOM Protocol is designed for controlling different Beijer Electronics device
Command Reference20 Beijer Electronics, MAEN9935.5 TYPUnit Type and Model NumberQueries the device type and model.Supported since Firmware VersionLAUE
Command ReferenceBeijer Electronics, MAEN993 215.6 LAULauer ExtensionThe Lauer Extension is a new SCOM command specially developed for Beijer Elec-tro
Command Reference22 Beijer Electronics, MAEN993Response Message (Acknowledge)The following sections describe all supported LAU sub-commands in each fu
Command ReferenceBeijer Electronics, MAEN993 235.6.1 LAU_CONFIG_GETFWVERSION (0x0101)Firmware VersionReturns the current firmware name and version inc
Command Reference24 Beijer Electronics, MAEN9935.6.2 LAU_CONFIG_GETMANUFACTURER (0x010C)ManufacturerRequests the manufacturer ID from the device. The
Command ReferenceBeijer Electronics, MAEN993 255.6.3 LAU_CONFIG_GETDEVICENAME (0x010D)Device NameReturns the device type and model. Actually, this com
Command Reference26 Beijer Electronics, MAEN9935.6.4 LAU_CONFIG_GETDILMODE (0x010E)DIL Switch ModeFor a base configuration, Beijer Electronics RBCs ar
Command ReferenceBeijer Electronics, MAEN993 275.6.5 LAU_CONFIG_GETDISPLAYADR (0x010F)Device AddressReturns the software configured device address. Th
Command Reference28 Beijer Electronics, MAEN9935.6.6 LAU_CONFIG_GETCOMSERMODE (0x0110)SCOM Serial Interface ModeThe serial interface mode indicates th
Command ReferenceBeijer Electronics, MAEN993 295.6.7 LAU_CONFIG_GETPOTMODE (0x0113)POT ModeReturns the local backlight level control configuration. If
ContentsBeijer Electronics, MAEN993 IContents1 Interface Configuration 52 Message Format and Description 63 Device Addressing 84 Protocol Description
Command Reference30 Beijer Electronics, MAEN9935.6.8 LAU_CONFIG_GETREMOTECONTROL (0x011C)Remote Control ConfigurationThis command returns the configur
Command ReferenceBeijer Electronics, MAEN993 315.6.9 LAU_CONFIG_GETSTARTUPBRIGHTNESSMODE (0x0124)Startup Brightness ModeThe Beijer Electronics RBCs ca
Command Reference32 Beijer Electronics, MAEN993Example Check which mode the backlight of the device at address 0.7 (group 0, address 7) has at startup
Command ReferenceBeijer Electronics, MAEN993 335.6.10LAU_CONFIG_GETSERIALNUMBER (0x0125)Serial NumberReturns the serial number of the device.Supported
Command Reference34 Beijer Electronics, MAEN9935.6.11LAU_CONFIG_GETDEFAULTBRIGHTNESS (0x0126)Startup Brightness ModeFor the Beijer Electronics RBCs a
Command ReferenceBeijer Electronics, MAEN993 355.6.12LAU_CONFIG_GETDISPLAYGROUP (0x0127)Device GroupBesides the standard addressing scheme, where the
Command Reference36 Beijer Electronics, MAEN9935.6.13LAU_CONFIG_GETKEYPRESSMODE (0x012A)Keypress ModeThe brightness of the Beijer Electronics RBCs can
Command ReferenceBeijer Electronics, MAEN993 37Example Check the keypress mode of the device at address 0.3 (group 0, address 3):According to the data
Command Reference38 Beijer Electronics, MAEN9935.6.14LAU_CONFIG_SETDILMODE (0x018E)DIL Switch ModeFor a base configuration, Beijer Electronics RBCs ar
Command ReferenceBeijer Electronics, MAEN993 39Example Set the device at address 0.7 (group 0, address 7) in the mode to override the DIL settings (i.
ContentsII Beijer Electronics, MAEN9935.6.27 LAU_STATUS_POTMODE (0x0304) . . . . . . . . . . . . . . . . . . . . . .615.6.28 LAU_STATUS_BUZZER (0x0306
Command Reference40 Beijer Electronics, MAEN9935.6.15LAU_CONFIG_SETDISPLAYADR (0x018F)Device AddressStores a software address of a device in the inter
Command ReferenceBeijer Electronics, MAEN993 41Example Set the software configured device address (excluding group) from the device at ad-dress 14.7 (
Command Reference42 Beijer Electronics, MAEN9935.6.16LAU_CONFIG_SETCOMSERMODE (0x0110)SCOM Serial Interface ModeThe serial interface mode indicates th
Command ReferenceBeijer Electronics, MAEN993 43Response Message (Negative Acknowledge)Under normal operation conditions, a device never sends a negati
Command Reference44 Beijer Electronics, MAEN9935.6.17LAU_CONFIG_SETREMOTECONTROL (0x019C)Remote Control ConfigurationThis command returns a configurat
Command ReferenceBeijer Electronics, MAEN993 45Example Check if the device at address 0.7 (group 0, address 7) is configured to remote control other d
Command Reference46 Beijer Electronics, MAEN9935.6.18LAU_CONFIG_SETSTARTUPBRIGHTNESS MODE (0x01A4)Startup Brightness ModeThe Beijer Electronics RBCs c
Command ReferenceBeijer Electronics, MAEN993 47Response Message (Negative Acknowledge)Under normal operation conditions, a device never sends a negati
Command Reference48 Beijer Electronics, MAEN9935.6.19LAU_CONFIG_SETSERIALNUMBER (0x01A5)Serial NumberSets the serial number of the device. This functi
Command ReferenceBeijer Electronics, MAEN993 495.6.20LAU_CONFIG_SETDEFAULTBRIGHTNESS (0x01A6)Default BrightnessA default brightness can be stored for
Interface ConfigurationBeijer Electronics, MAEN993 51 Interface Configuration A command can be sent either using the serial interface (RS232 or RS485)
Command Reference50 Beijer Electronics, MAEN993Maximum Lr for this Command9Example Set the default brightness of the device at address 0.7 (group 0, a
Command ReferenceBeijer Electronics, MAEN993 515.6.21LAU_CONFIG_SETDISPLAYGROUP (0x01A7)Device GroupBesides the standard addressing scheme, where the
Command Reference52 Beijer Electronics, MAEN993Example Write the new display group to the device at address 14.7 (group 14, address 7), which is effec
Command ReferenceBeijer Electronics, MAEN993 535.6.22LAU_CONFIG_SETKEYPRESSMODE (0x01AA)Keypress ModeThe brightness of the Beijer Electronics RBCs can
Command Reference54 Beijer Electronics, MAEN993Response Message (Acknowledge)Response Message (Negative Acknowledge)Under normal operation conditions,
Command ReferenceBeijer Electronics, MAEN993 555.6.23LAU_CONTROL_BUZZER (0x0202)Buzzer ControlActivates the built-in buzzer, if available.Supported si
Command Reference56 Beijer Electronics, MAEN993Example Enable the buzzer of the device at address 0.7 (group 0, address 7):The device at address 0.7 (
Command ReferenceBeijer Electronics, MAEN993 575.6.24LAU_CONTROL_RESET (0x0207)Software ResetThis commands resets the software. All software initializ
Command Reference58 Beijer Electronics, MAEN9935.6.25LAU_STATUS_DISPLAYADR (0x0302)Current Device AddressReturns the current device address. If the DI
Command ReferenceBeijer Electronics, MAEN993 595.6.26LAU_STATUS_SCOMSERMODE (0x0303)Current SCOM Serial Interface ModeThe serial interface mode indica
Message Format and Description6 Beijer Electronics, MAEN9932 Message Format and DescriptionAn SCOM message is a stream of bytes, containing the destin
Command Reference60 Beijer Electronics, MAEN993Example Read the current serial interface mode of the device at address 0.7 (group 0, address 7):Accord
Command ReferenceBeijer Electronics, MAEN993 615.6.27LAU_STATUS_POTMODE (0x0304)Current POT ModeMost of our devices have a potentiometer or two button
Command Reference62 Beijer Electronics, MAEN9935.6.28LAU_STATUS_BUZZER (0x0306)Current Buzzer StateReturns the current buzzer state. The buzzer state
Command ReferenceBeijer Electronics, MAEN993 635.6.29LAU_STATUS_BACKLIGHT (0x0307)Current Backlight StateReturns the current backlight level value.Sup
HEAD OFFICESWEDENBeijer Electronics Products ABBox 426SE-201 24 Malmö, SwedenTel: +46 40 35 86 00Fax: +46 40 93 23 [email protected]
Message Format and DescriptionBeijer Electronics, MAEN993 7As shown in the table, the DATA field is optional. If the message does not require any data
Device Addressing8 Beijer Electronics, MAEN9933 Device Addressing By default, a Beijer Electronics RBC supports the standard SCOM addressing scheme, w
Protocol Description and TimingsBeijer Electronics, MAEN993 94 Protocol Description and TimingsThe protocol used for transferring SCOM messages and re
Commentaires sur ces manuels