Hardware Replacement
MODE Description
1100 Notused(runmode).
1110 Self-test.
xxx1 Hardreset(forcesthesystemtorese t).
To ch ange mode switches, follow the steps below:
1.
Disconnect power from the op erator panel.
2.
Set the mode switches using a ballpoint pen.
3.
Reconnect power to the operator panel.
8.2 Cables
Mostoftheoperatorpanelsusethesametypeofflexcableconnectors.
connector flanges
Flex cable connector
To release the flex cables from the connector, gently push the two flanges on the
cable connector towards the flex cable.
Note:
Theconnectorsmustbeunlockedonbothsidesbeforeremovingthecable,otherwise
theexcablemaybedamaged.